Welcome to ZTA POWER COMPANY
Brand:
Chongqing CumminsItem NO.:
BC1825Order(MOQ):
1Payment:
T/T 30%, 70% or LC 100% at sight.Price Range:
141000 - 158000/$1Product Origin:
ChinaShipping Port:
Xiamen, ChinaLead Time:
2-4 weeksProduct Detail
About US
AI Power Factory Introduction
High quality, reliable and complete power unit
Compact design
Easy start and maintenance possibility
Every generating set is subject to a comprehensive test program which includes full load testing, checking and provision of all control and safety shut down functions testing
Fully engineered with a wide range of options and accessories: Canopy, sound proof canopy and on - road trailer
Diesel generator Details | |
Model | CLK-1500GF |
Power | 1500kva |
Frequency | 50HZ |
Voltage | 380/220v(voltage can be customized) |
Optional Type | Open/soundproof/trailer |
Size of Open type | 12000*2400*2900mm |
Weight of Open type | 10300kg |
With Diesel Engine | |
Brand&model |
Cummins KTA50-GS8 |
Standby Power | 1200kw |
Cylinders | V-16 |
Bore*Stroke | 159*159mm |
Displacement | 50L |
Lubrication Oil Capacity | 135L |
Fuel Consumption at 100% Load | 204g/kw.h |
Speed Governor | Electric |
With Alternator | |
Optional Brands | Stamford/Leroy Somer/Hengsheng/Marathon |
Exciter type | Single bearing,brushless,Self-excited |
Power factor | 0.8 |
Voltage adjust range | ≥5% |
Insulation Grade | H |
Protection Grade | IP23 |
With Controller | |
Optional brands | Deepsea/ComAp/Smartgen |
RFQ:
Generator set grounding system
In order to ensure personal safety and the needs of power system work, there are strict requirements for 1 mega power generator grounding.
There are three grounding modes: working grounding, protective grounding and protective neutral grounding. The purpose of grounding is as follows:
1. Working grounding
Working grounding is to ground the neutral point, and its purpose is to:
1) Reduce the electric shock voltage. For the system with ungrounded neutral point, when one phase is grounded and the human body touches one of the other two phases, the medium voltage is more than 1.7 times of the phase voltage; For neutral grounding system, the electric shock voltage drops to close to or equal to phase current
2) Quickly cut off the faulty equipment. For the system with ungrounded neutral point, when one phase is grounded, the current path can be formed due to the capacitance and insulation resistance between the conductor and the ground. The grounding current is very small, which is not enough to make the protective device act and cut off the power supply, so as to ensure personal safety. For the neutral grounded system, when one phase is grounded, the grounding current is large, and the protection device will act quickly to disconnect the fault point.
3) Reduce the insulation level of electrical equipment to ground. In a neutral ungrounded system, when one phase is grounded, the ground voltage of the other phase C will rise to the line voltage. For the neutral grounded system, when one phase is grounded, the other two phases are only close to the phase voltage, so the insulation level of electrical equipment and transmission line can be reduced.