• Rated Power Absorbed Power Oct 28, 2024
    Electric Motor Absorbed Power Estimation Very often one needs to know the power absorbed by say, a pump or a carrier or fan or some other equipment driven by an electric motor. If one has a three-phase electric power meter and one measures the three phase currents and voltages then the power can be calculated directly. Most often however all one has is the current reading from the MCC panel ammete...
  • Fault Currents and Short Circuit Decrement Curves Sep 25, 2024
    Fault Currents and Short Circuit Decrement Curves A generating set operating in service will be connected to a distribution system serving the connected load[s]. This distribution system has impedance, and so will introduce a value of Z between the alternator terminals and the point at which the ‘fault’ has occurred. The ‘fault’ will also have a value of Z, and if the nature of the ‘fault’ is an ‘...
  • The inspection before starting the diesel generator set Aug 30, 2024
    The inspection before starting the diesel generator set is the basis for ensuring its normal operation, and whether the diesel generator can start normally is the key to ensuring its normal operation. Below, based on the starting conditions of diesel generators, we will introduce the factors that affect the starting of diesel generators and relevant precautions. 1. Conditions for starting diesel g...
  • OVERVIEW OF PROTECTION SYSTEMS FOR ALTERNATOR Jul 25, 2024
    SYSTEM 2 System 2 is used when the alternator environment is very likely to be damp. This system primarily concerns the windings, which are given a special treatment. It should be noted that this treatment protects the windings effectively against all  This flexible coating is only applied to the lower parts of the stator. Feedback from the field has shown this area to be the most vulnerable ...
  • Efficiency, parameters and environmental factors of generator sets Jul 02, 2024
    In some places, due to strong sandstorms or high levels of dust in the air. Summary: As is well known, synchronous generators have magnetic poles on their rotors, while asynchronous ones do not. This is equivalent to relying on magnetic poles to save excitation energy, so synchronous generators have high efficiency. The difference between asynchronous generators and synchronous generators is that ...
  • electronic speed regulator for Cummins power Apr 09, 2024
    Design and implementation of electronic speed regulator for Cummins power equipment diesel generator Design and implementation of electronic speed regulator for Cummins power diesel generator. As an important main power supply or backup power supply, diesel generators have been increasingly widely used in military, shipbuilding, aviation and other fields. The stability of diesel engine speed helps...
  • Self-starting unit Generator Set Mar 12, 2024
    Self-starting unit generator set This unit adds an automatic control system on the basis of the basic mechanism, and it has automated functions. When the external source (mains power) suddenly fails, the unit can automatically start, automatically perform switch switching, automatic operation, automatic power supply and automatic parking: when the oil pressure is too low, the oil temperature or th...
  • Feb 21, 2024
    What issues to pay attention to when using Cummins diesel generators in cold regions   When using Cummins diesel generator sets in cold regions, the following issues should be noted: ① When supplying power to the unit, it is required to place it flat so that the cooling water inside the lubricating oil radiator can be drained completely. ② After draining the engine, start the diesel generator...
  • Classification Of Performance Levels For Generator Sets Jan 10, 2024
    1) Performance G1 level - This level is required to be applicable to loads that only require the basic parameters of voltage and frequency to be specified. Generally used for lighting and other simple electrical equipment. 2) Performance G2 level - This level is required to apply to loads that have the same voltage characteristics as the public power system. When the load changes, there may be all...
  • Analysis and solutions to the causes of electromagnetic Nov 29, 2023
    interference in motors 1 Causes of electromagnetic interference (1) Interference or aging due to sudden changes in the magnetic field in the windings If the current path through the motor coil windings is cut off, the magnetic field in the coils suddenly disappears, and hundreds of volts will be generated on the coils. , even transient overvoltage of thousands of volts. This voltage produces a hug...
1 2 3 4 5 6