Welcome to ZTA POWER COMPANY
500KVA Weichai Induction Generator German Company:
Weichai Engine Model:6M26D484E200
Order(MOQ):
1Price:
$28000/32000Product Origin:
ChinaShipping Port:
XiamenLead Time:
3-4weeksProduct Detail
With the technical strength of global R&D center, Weichai Power created a new generation of powerhouse generator manufacturer industrial power product to satisfy the power demand of six large supporting domains: Power for land based, power generation, Power for marine, power generation, Power for marine emergency, power generation,Power for Passenger vehicle, Power for air compressor.
Assembled by 500kva weichai emergency power diesel engine and Leroy Somer alternator
Weichai Engine Main technical parameters
Manufacturer | WEICHAI POWER CO. LTD | ||||||||||||||||||||||
Model | 6M26D484E200 | ||||||||||||||||||||||
Engine speed | 1500rpm | ||||||||||||||||||||||
Engine power | 440KW | ||||||||||||||||||||||
Type | In-line、4-Strokes、Water cooled、Turbocharged and Intercooled | ||||||||||||||||||||||
No. of cylinders / valves | 6/24 | ||||||||||||||||||||||
Bore/Stroke | 150mm/150mm | ||||||||||||||||||||||
Compression Ratio | 15:01 | ||||||||||||||||||||||
Displacement | 15.9L | ||||||||||||||||||||||
Rated Power | 440kW | ||||||||||||||||||||||
Overload Power | 484kW | ||||||||||||||||||||||
Idle Speed | 700±30 r/min | ||||||||||||||||||||||
Fire Sequence | 1-5-3-6-2-4 | ||||||||||||||||||||||
Crankshaft Rotating Direction | Counterclockwise facing flywheel | ||||||||||||||||||||||
Starting method | DC24V Electrical Start | ||||||||||||||||||||||
Starting motor Power/voltage | 7.5kW/24V | ||||||||||||||||||||||
Governing control | Electrical speed governor | ||||||||||||||||||||||
Cooling mode | water cooled | ||||||||||||||||||||||
Min. coolant temperature of engine working | 50℃ | ||||||||||||||||||||||
Coolant capacity | 40L | ||||||||||||||||||||||
The capacity of oil sump | 50L(follow the oil dipstick) | ||||||||||||||||||||||
Net weight | 1600 | ||||||||||||||||||||||
Size of shape (length×width×height) : | 2262x1224x1551 (outline drawing) |
500 kva generator fuel consumption
Steady governing rate | Electronic:≤3% | ||||||||||||||||||||||
Rated speed fluctuation rate | ≤0.5% | ||||||||||||||||||||||
Idling speed fluctuation rate | ≤4.5% | ||||||||||||||||||||||
Fuel consumption at rated working condition | ≤210g/kW·h | ||||||||||||||||||||||
Consume ratio of oil and fuel | ≤0.5% | ||||||||||||||||||||||
Recommended service parameters of diesel engine:
Power output: | SAE1 flywheel housing/ 14 flywheel /178 Tooth | ||||||||||||||||||||||
Air filter flow | 2473m3/h | ||||||||||||||||||||||
Min. diameter of intake pipe | 140mm | ||||||||||||||||||||||
Min. diameter of exhaust pipe | 200mm | ||||||||||||||||||||||
Max. exhaust back pressure | 7.5kPa | ||||||||||||||||||||||
Max. exhaust temperature(After the turbocharger) | 580℃ | ||||||||||||||||||||||
Alarm value of low oil temperature | 200 kPa | ||||||||||||||||||||||
Alarm value of high oil temperature | 1000kPa | ||||||||||||||||||||||
Please measure oil pressure after running 30s | |||||||||||||||||||||||
Alarm value of water outlet temperature | 95℃ | ||||||||||||||||||||||
Stopping value of high speed | 115% rated speed | ||||||||||||||||||||||
Min. diameter of fuel inlet pipe | 12mm | ||||||||||||||||||||||
Cooling system resistance of engine external (Rated working condition) | 50kPa |
Alternator Specifications:
Manufacturer | Leroy-somer Electro-technique (Fuzhou) Company Ltd. | ||||||||||||||||||||||
Model | TAL-A47-C | ||||||||||||||||||||||
Output power | 400KW | ||||||||||||||||||||||
AVR model | R150 | ||||||||||||||||||||||
Number of phase | 3 | ||||||||||||||||||||||
Power factor (Cos Phi) | 0.8 | ||||||||||||||||||||||
Altitude | ≤ 1000 m | ||||||||||||||||||||||
Overspeed | 2250RPM | ||||||||||||||||||||||
Number of Pole | 4 | ||||||||||||||||||||||
Exciter type | Shunt | ||||||||||||||||||||||
Insulation class | H | ||||||||||||||||||||||
Voltage regulation | ±0.5% | ||||||||||||||||||||||
Protection | IP23 | ||||||||||||||||||||||
Totale Harmonic distortion THD (**) | no load < 1.5% | ||||||||||||||||||||||
Totale Harmonic distortion THD (**) | on load < 2% | ||||||||||||||||||||||
Waveform: NEMA = TIF | < 50 | ||||||||||||||||||||||
Bearing | single | ||||||||||||||||||||||
Coupling | Direct |
With durability, high performance and good operating economy, engines of emergency standby generator system obtain apparels from domestic and foreign customer.